30" (76 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
WFG231LV
Gas supply: Provide a gas supply line of 3/4" (1.9
cm) rigid pipe to the range location. A smaller size
pipe on longer runs may result in insufficient gas
supply. Pipe-joint compounds that resist the action of
LP gas must be used. Do not use TEFLON® tape. With
LP gas, piping or tubing size can be 1/2" (1.3 cm)
minimum. Usually, LP gas suppliers determine the
size and materials used in the system.
If local codes permit, a new CSA design-certified, 4 to
5 ft (122 to 152.4 cm) long, 1/2" (1.3 cm) or 3/4" (1.9
cm) I.D., flexible metal appliance connector may be
used for connecting range to the gas supply line.
D
A
A. 36" (91.4 cm)
E
B. 29⁷⁄₈" (75.9 cm)
C. 24¼" (61.6 cm)
D. 25¾" (65.6 cm)
E. 46¼" (117.5 cm)
A 1/2" (1.3 cm) male pipe thread is needed for
connection to the female pipe threads of the inlet to
the appliance pressure regulator.
The supply line must be equipped with a manual
shutoff valve. This valve should be located in the
same room but external to the range. It should be in a
location that allows ease of opening and closing. Do
not block access to shutoff valve. The valve is for
turning on or shutting off gas to the range.
B
C
Electrical: A 120-volt, 60 Hz, AC-only, 15 amp,
fused electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this range be provided.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth,
24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
D
If the cabinet depth is greater than 24" (61.0 cm), oven frame must extend
beyond cabinet fronts by 1/2" (13.0 mm) minimum.
B
C
IMPORTANT: If installing a range hood or microwave hood combination
above the range, follow the range hood or microwave hood combination
installation instructions for dimensional clearances above the cooktop
surface.
A
E
A. 18" (45.7 cm) min. clearance upper side cabinet to countertop
B. 13" (33.0 cm) max. upper cabinet depth
C. 30" (76.2 cm) min. cabinet opening width
H
G
D. For minimum clearance to top of cooktop, see NOTE*.
E. 30¹⁄₈" (76.5 cm) min. opening width
F. This shaded area recommended for installation of electrical outlet.
G. This shaded area recommended for installation of rigid gas pipe.
H. 2" (5.1 cm) min. countertop space to side wall or other combustible
material
J
I
I. 24" (61.0 cm)
J. 10" (25.4 cm)
K. 8" (20.3 cm)
L. 5" (12.7 cm)
M. 2" (5.1 cm)
N. 3" (7.6 cm)
F
K
M
L
L
N
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is
covered by not less than 1/4" (0.64 cm) flame retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform
and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10200946
07-30-08
|